# Nitrosamine impurities

> A group of chemical impurities, such as NDMA, many of which are classed as probable human carcinogens. Regulators require manufacturers to assess and control them in medicines.

Nitrosamines came to regulatory attention in 2018, when NDMA was found in some valsartan products. Related findings followed in other medicines, including ranitidine and metformin, and led to recalls in several countries. Regulators including the European Medicines Agency, the US FDA and WHO have since asked manufacturers to assess the risk across their products, test where a risk is identified and keep any nitrosamine within an acceptable intake limit.

## Where they come from

- The synthesis route of the [API](https://pharmasetu.com/glossary/api), including certain solvents, reagents and recovered materials
- Reactions between the active ingredient and traces of nitrite in excipients, during manufacture or storage
- In some cases, packaging materials

## Why an importer cares

Many regulators now ask for a nitrosamine risk assessment at registration or as a commitment afterwards. Limits and expectations are still developing and differ between authorities, so confirm what yours requires.

## What to ask the supplier for

- The manufacturer's risk assessment statement for the product
- Confirmatory test results where a risk was identified
- Notice of any change in API source, which can change the risk

A routine [CoA](https://pharmasetu.com/glossary/certificate-of-analysis) lists a nitrosamine test only if it is part of the product specification, so its absence there does not mean the assessment was skipped. Our [quality](https://pharmasetu.com/quality) page explains which documents are reviewed.

---

Source: https://pharmasetu.com/glossary/nitrosamine-impurities - PharmaSetu - Trade information for licensed buyers, not medical advice. [Request a quote](https://pharmasetu.com/request-a-quote)